Junior-PAM
Entry level PAM-Fluorometer for teaching classes and workshops
The JUNIOR-PAM is an entry-level Pulse-amplitude modulated (PAM) chlorophyll fluorometer which can perform full-range of photosystem II saturation pulse analysis. Available in blue and white versions, both are equipped with a far-red LED with a maximum emission around 745 nm and an emission range from 675-800n nm which is needed for determination of F0’ level fluorescence.
About the systems
The BLUE version is the standard configuration of the JUNIOR-PAM and is well suited for fluorescence measurements in most eukaryotic algae and higher plants. However, for algae that absorb weakly in the blue range, such as certain species within the phylum cyanobacteria, the WHITE version provides substantially stronger fluorescence signals compared to the BLUE version.Included in the package
- Optoelectronic Unit
- Data Acquisition System
- Mini Quantum Sensor
- Software WinControl-3 installer
- Light guide
- Open leaf clip and magnetic leaf clip
- Fluorescence standard
- Polishing set
- USB-cable
- Transport case (29 cm x 25 cm x 6 cm)
Specification
| Parameters | JUNIOR-PAM/B | JUNIOR-PAM/W |
| Modulated fluorescence excitation | Blue LED (wavelength of maximum emission: 445 nm). Modulation frequencies 5 to 25 Hz adjustable in increments of Hz, and 100 Hz. Fluorescence at wavelengths greater than 630 nm is measured | White LED (wavelengths of maximum emission: 445 and 545 nm). Modulation frequencies 5 to 25 Hz adjustable in increments of 5 Hz, and 100 Hz. Fluorescence at wavelengths greater than 650 nm is measured |
| Actinic Light | Same LED as used for modulated light. PAR at 1 mm distance from the tip of the 50 cm JUNIOR-PAM light guide: 25 to 1500 µmol m-2s-1. Maximum PAR saturation pulses, 7000 µmol m-2s-1 | Same LED as used for modulated light. PAR at 1 mm distance from the tip of the 50 cm JUNIOR-PAM light guide: 25 to 1500 µmol m-2s-1. Maximum PAR saturation pulses, 4000 µmol m-2s-1 |
| Far-red light | LED with 745 nm maximum emission wavelength | |
| Fluorescence Detection | PIN photodiode protected by long-pass filter. Selective window amplifier to measure PAM fluorescence | |
| Power Supply | 5V DC supplied by the USB cable type A-B used for communication | |
| Light Guide | Length: 50 cm Diameter: 1.5 mm | |
| Operating Temperature | 0 to 40 deg C | |
| Operating Humidity Range | 35 to 85% RH | |
Optional Accessories
- Monitoring Leaf-Clip
- Extra-long light guide (100 cm)
Support Documents
Case Studies and Application Notes
-
No case studies found
Related Products
Recommended Products

MINI-PAM-II Photosynthesis Yield Analyzer
Select options
This product has multiple variants. The options may be chosen on the product page