Weighing Lysimeter with ET Station
Advanced monitoring system for measure hydrological fluxes
A fully integrated weighing lysimeter system for the measurement of hydrological flux between soil, plant, and atmosphere comprising the measurement of plant water use and (optionally) evapotranspiration simultaneously.
A high precision weighing lysimeter system available with various load cell ranges. Optionally includes integrated ET weather station for the measurement of ET.
Sensor combinations are built around three tiers of products, providing increasingly responsive and accurate solutions.
| Parameter | Tier 1 (Good)
Indicative / Observation |
Tier 2 (Better)
Decision |
Tier 3 (Best)
Research / Benchmark |
|
| Lysimeter | Weigh Scale | SDI-12 Weigh Scale | SDI-12 Weigh Scale | SDI-12 Weigh Scale |
| Drain measure | PRS-02 | PRS-02 | PRS-02 | |
| 2x Soil Water Potential | Tensiometer | TM7 | TM7 | |
| 2x Soil Moisture Sensors | SMT-100D | TDR-310/315 | TDR-310/315 | |
| Optional ET Weather Station | Wind | Calypso | Windsonic | Windsonic 75 |
| Rain | PRP-02 | RIM-7499-STD | RIM-7499-BOM | |
| Pyranometer | SP-421 | SP-421 | SP-421 | |
| Soil (Single) | SMT-100 | TDR-310/315 | TDR-310/315 | |
| Plant Water Use | SDI-12 Sap Flow | SDI-12 Sap Flow | SDI-12 Sap Flow | |
| Crossarm | Yes | Yes | Yes | |
| Power system | LP | LP | LP | |
| Part Number | WL-T1
WLWS-T1 |
WL-T2
WLWS-T2 |
WL-T3
WLWS-T3 |
|
Weighing Lysimeter with ET Station
About the Complete Irrigation Scheduling System:
All systems are built upon the ICT International Datalogger, which is optimised for the DB2 data handling platform. Providing an all-in-one datalogger, with power management and data handling, the datalogger platform is expandable with optional communication and sensor expansion modules.
The systems contain all parts required for the installation of the system, enabling the deployment of the system from the box.
All systems are built upon the ICT International Datalogger, which is optimised for the DB2 data handling platform. Providing an all-in-one datalogger, with power management and data handling, the datalogger platform is expandable with optional communication and sensor expansion modules.
The systems contain all parts required for the installation of the system, enabling the deployment of the system from the box.
Data
The Complete Irrigation Scheduling Systems measure the following parameters which can be visualised in the DB2 platform:
| Part Number | WL-T1
WLWS-T1 |
WL-T2
WLWS-T2 |
WL-T3
WLWS-T3 |
|
| Lysimeter | Weigh Scale | |||
| Drain measure | ||||
| 2x Soil Water Potential | MPa of soil water potential | Soil water tension and soil temperature | Soil water tension and soil temperature | |
| 2x Soil Moisture Sensors | ||||
| ET | Temp / Humidity / VPD | Direct measure:
Temperature Humidity Calculated: Wet Bulb Temperature Dew point VPD Relative humidity, temperature, dew/frost point temperature, wet bulb temperature, absolute humidity, mixing ratio, enthalpy |
Direct measure:
Temperature Humidity Calculated: Wet Bulb Temperature Dew point VPD Relative humidity, temperature, dew/frost point temperature, wet bulb temperature, absolute humidity, mixing ratio, enthalpy |
Direct measure:
Temperature Humidity Calculated: Wet Bulb Temperature Dew point VPD Relative humidity, temperature, dew/frost point temperature, wet bulb temperature, absolute humidity, mixing ratio, enthalpy |
| Wind | ||||
| Rain | Daily rainfall (user defined time – default to 9am)
Visualisations: Cumulative rainfall Daily rainfall Intensity |
Daily rainfall (user defined time – default to 9am)
Visualisations: Cumulative rainfall Daily rainfall Intensity |
Daily rainfall (user defined time – default to 9am)
Visualisations: Cumulative rainfall Daily rainfall Intensity |
|
| Pyranometer | Solar Radiation in | |||
| Metadata | Geolocation | Accurate to 5 decimal places (approximately 1.11 metres, depending on installation conditions) | Accurate to 5 decimal places (approximately 1.11 metres, depending on installation conditions) | Accurate to 5 decimal places (approximately 1.11 metres, depending on installation conditions) |
| Â | Â | Tier 1 (Good) Indicative / Observation |
Tier 2 (Better) Decision |
Tier 3 (Best) Research / Benchmark |
||||||||||||
| Part Number | IS-T1 | IS-T2 | IS-T3 | |||||||||||||
| Parameter | Sensor | Range / Accuracy / Detail | Value | Sensor | Range / Accuracy / Detail | Value | Sensor | Range / Accuracy / Detail | Value | |||||||
| SPAC | Weigh Scale | SDI-12 Weigh Scale | Measuring Range | SDI-12 Weigh Scale | Measuring Range | SDI-12 Weigh Scale | Measuring Range | |||||||||
| Resolution | Resolution | Resolution | ||||||||||||||
| Accuracy | Accuracy | Accuracy | ||||||||||||||
| Drain measure | PRS-02 | Measuring Range | PRS-02 | Measuring Range | PRS-02 | Measuring Range | ||||||||||
| Resolution | Resolution | Resolution | ||||||||||||||
| Accuracy | Accuracy | Accuracy | ||||||||||||||
| 2x Soil Water Potential | Tensiometer | Measuring Range | +100kPa to -100kPa | TM7 | Measuring Range | 1-1,000 mPa (pF 0 to pF 7.0) | TM7 | Measuring Range | 1-1,000 mPa (pF 0 to pF 7.0) | |||||||
| Resolution | 0.1 kPa | Resolution | 0.01 pF | Resolution | 0.01 pF | |||||||||||
| Accuracy | ±1.0% span | Accuracy | +/- 30 hPa & 5 % FS = 0.35 pF | Accuracy | +/- 30 hPa & 5 % FS = 0.35 pF | |||||||||||
| 2x Soil Moisture Sensors | SMT-100D | Soil Moisture | Range | 0 to 60% volumetric water content
(up to 100% volumetric water content with limited accuracy) |
TDR-310/315 | Soil Moisture | Range | TDR-310/315 | Soil Moisture | Range | ||||||
| Resolution | 0.1% volumetric water content or better | Resolution | Resolution | |||||||||||||
| Accuracy | Using factory calibration up to ± 3% (VWC) in mineral soils with moderate salinity from 0 to 50% VWC
Using medium specific calibration up to ± 1% (VWC) |
Accuracy | Accuracy | |||||||||||||
| Soil Temp | Range | -40 to +80°C | Soil Temp | Range | Soil Temp | Range | ||||||||||
| Resolution | 0.01°C or better | Resolution | Resolution | |||||||||||||
| Accuracy | Typical ± 0.2°C, max. ± 0.4°C over full range | Accuracy | Accuracy | |||||||||||||
| ET | Temp / Humidity | Vaisala HMP60 | Range (temp) | −40 … +60 °C | Vaisala HMP110 | Range (temp) | −40 … +80 °C | Vaisala HMP155 | Range (temp) | −80 … +60 °C | ||||||
| Accuracy (temp) | +10 … +30 °C | ±0.5 °C | Accuracy (temp) | +15 … +25 °C | ±0.1 °C | Accuracy (temp) | At −80 … +20 °C | ±(0.176 – 0.0028 × temp) °C | ||||||||
| at +10 … +30 °C | ±0.5 °C | 0 … +15 °C and +25 … +40 °C | ±0.15 °C | At +20 … +60 °C | ±(0.07 + 0.0025 × temp) °C | |||||||||||
| −40 … 10 °C and +30 … +60 °C | ±0.6 °C | −40 … 0 °C and +40 … +80 °C | ±0.4 °C | |||||||||||||
| Range (humidity) | 0–100 %RH | Range (humidity) | 0–100 %RH | Range (humidity) | 0–100 %RH | |||||||||||
| Accuracy (humidity) | 0 … +40 °C | ±3 %RH (0–90 %RH)
±5 %RH (90–100 %RH) |
Accuracy (humidity) | 0 … +40 °C | ±1.5 %RH (0–90 %RH)
±2.5 %RH (90–100 %RH) |
Accuracy (humidity) | At +15 … +25 °C | ±1 %RH (0 … 90 %RH)
±1.7 %RH (90 … 100 %RH) |
||||||||
| at −40 … 0 °C and +40 … +60 °C | ±5 %RH (0–90 %RH)
±7 %RH (90–100 %RH) |
at −40 … 0 °C and +40 … +80 °C | ±1.1 %RH (0–90 %RH)
±1.8 %RH (90–100 %RH) |
At −20 … +40 °C | ±(1.0 + 0.008 × reading) %RH | |||||||||||
| At −40 … −20 °C | ±(1.2 + 0.012 × reading) %RH | |||||||||||||||
| At +40 … +60 °C | ±(1.2 + 0.012 × reading) %RH | |||||||||||||||
| At −60 … −40 °C | ±(1.4 + 0.032 × reading) %RH | |||||||||||||||
| Replaceable Calibration Chip | Yes | Replaceable Calibration Chip | Yes | Replaceable Calibration Chip | Yes | |||||||||||
| Wind | Calypso | Speed: Range | 0.5-45 m/s | Windsonic | Speed: Range | 0 – 60 m/s | Windsonic 75 | Speed: Range | 0 – 75 m/s | |||||||
| Speed: Accuracy | ± 0.3 m/s up to 10m/s and 3% from 10 to 45m/s | Speed: Accuracy | 2% RMSE @12 m/s | Speed: Accuracy | 2% RMSE @12 m/s | |||||||||||
| Speed: Resolution | 0.01 m/s | Speed: Resolution | 0.01 m/s | |||||||||||||
| Direction: Range | 0-360º | Direction: Range | 0 – 360° (no dead band) | Direction: Range | 0 – 360° (no dead band) | |||||||||||
| Direction: Accuracy | ± 1º | Direction: Accuracy | 2° RMSE @12 m/s | Direction: Accuracy | 2° RMSE @12 m/s | |||||||||||
| Direction: Resolution | 1° | Direction: Resolution | 0.1° (output at 0, 1 or 2
decimal places) |
|||||||||||||
| Rain | PRP-02 | Collector Area | 200cm2 | RIM-7499-STD | Collector Diameter | 203 mm ± 0.2mm | RIM-7499-BOM | Collector Diameter | 203 mm ± 0.2mm | |||||||
| Resolution | 0.2mm | Resolution | 0.2mm | Resolution | 0.2mm | |||||||||||
| Accuracy | ±2%, to a maximum 144 mm/hr | Accuracy | ±3% to 250mm/hr
±4% from 251mm/hr to 350mm/hr |
Accuracy | ±2% to 250mm/hr
±4% from 250mm/hr to 350mm/hr |
|||||||||||
| Materials: Collector | Acrylonitrile Styrene Acrylate | Materials | Collector: Copper | Materials | Collector: Copper | |||||||||||
| Bucket: Gold Plated Brass | Bucket: Gold Plated Brass | |||||||||||||||
| Jacket: Stainless Steel | Jacket: Stainless Steel | |||||||||||||||
| Base: Cast Marine Grade Aluminium | Base: Cast Marine Grade Aluminium | |||||||||||||||
| Pyranometer | SP-421 | Output Range | 0 to 2000 W mˉ² | SP-421 | Output Range | 0 to 2000 W mˉ² | SP-421 | Output Range | 0 to 2000 W mˉ² | |||||||
| Calibration Uncertainty at 1000 W mˉ² | Less than 3% | Calibration Uncertainty at 1000 W mˉ² | Less than 3% | Calibration Uncertainty at 1000 W mˉ² | Less than 3% | |||||||||||
| Measurement Repeatability | Less than 1 % | Measurement Repeatability | Less than 1 % | Measurement Repeatability | Less than 1 % | |||||||||||
| Non-stability (Long-term Drift) | Less than 2 % per yea | Non-stability (Long-term Drift) | Less than 2 % per yea | Non-stability (Long-term Drift) | Less than 2 % per yea | |||||||||||
| Spectral Range | 360 to 1120 nm (wavelengths where response is 10 % of maximum) | Spectral Range | 360 to 1120 nm (wavelengths where response is 10 % of maximum) | Spectral Range | 360 to 1120 nm (wavelengths where response is 10 % of maximum) | |||||||||||
| Power system | LP | Solar Panel | 10W | HP | Solar Panel | 20W | UHP | Solar Panel | 10W | |||||||
| Battery | 6,000mAh LiPO4 | Battery | 13,000mAh LiPO4 | Battery | 26,000mAh LiPO4 | |||||||||||
Tier 1 Sensors (IS-T1):
A low powered solution, these sensors are combined with a standalone data logger/communication system due to the very low power that these sensors consume. This low power consumption, combined with reliable and proven technologies make the ideal solution for widespread data collection networks across a study site.
- Lysimeter
- SDI-12 Weigh Scale
- PRS-02
- Tensiometer
- SMT-100D TDR-310/315Â Â Â TDR-310/315:
- Tensiometer: Providing measurements of the soil water potential, available in various lengths, the tensiometer measures the __________ that water can move through the soil.
- ET:
- Vaisala HMP60: For the measurement of vapour pressure deficit (VPD), a reliable, robust, and proven sensors is essential. The Vaisala HMP range of temperature and humidity sensors utilise a replaceable calibration chip that ensures high quality data is collected for the calculation of VPD – the atmospheric driver within the soil, plant, atmosphere continuum. The temperature/humidity sensor includes a matt radiation shield to reduce reflection, ensuring that there is minimal measurement interference.
- Wind (Calypso): A compact ultrasonic wind speed and direction sensor, the Calypso wind sensor measures gusts, direction, and speed at a user defined frequency. With no moving parts, the Calypso wind sensor is ideal for installation in long-term
- Rain (PRP-02): A robust tipping bucket rain gauge with 0.2 mm resolution, the PRP-02 is mounted on the crossarm, alongside the other sensors ensuring the station is easy to install and transport.
- Pyranometer (SP-421): With traceability to ISO9060, the Apogee SP-421 is a proven, reliable, calibrated pyranometer for the measurement of solar radiation.
- Power System: Supplied with the Low Power system containing a 10-watt solar panel and matching mount, and an internal 6,000mAh battery. The power system can be expanded with a supplementary 10-watt solar panel and mount to provide additional charge when used in low light conditions (EP-L).
Tier 2 Sensors (SPACWP-T2):
With external solar power, the Tier 2 sensors are ideal for long-term installation
- Lysimeter
- SDI-12 Weigh Scale
- PRS-02
- TM7 Tensiomark: An SDI-12 sensor that measures the soil water potential, the TM7 is a low maintenance sensor that is ideal for installation as part of a SPAC monitoring system.
- TDR-310/315:
- ET:
- Vaisala HMP110: The HMP110 builds upon the benefits of the HMP60, but is a higher accuracy for both humidity (±1.5 %RH vs ±3 %RH) and temperature (±0.1 °C vs ±0.5 °C)
- Wind (Windsonic): High performance ultrasonic wind speed and direction sensor,
- Rain (RIM-7499-STD):
- Pyranometer (SP-421):
- Power System: Supplied with the Low Power system containing a 10-watt solar panel and matching mount, and an internal 6,000mAh battery. The power system can be expanded with a supplementary 10-watt solar panel and mount to provide additional charge when used in low light conditions (EP-L).
Tier 3 Sensors (SPACWP-T3):
The Tier 3 sensors provide a high-quality research platform for detailed measurement of the soil-plant-atmosphere continuum. Integrating the SDI-12 Psychrometer for continuous non-destructive measurement of plant water potential, along with a highly responsive and accurate temperature humidity sensor, the tier 3 sensor suite provides the benchmark system for researchers to build their experiments around.
- Lysimeter
- SDI-12 Weigh Scale
- PRS-02
- TM7 Tensiomark: An SDI-12 sensor that measures the soil water potential, the TM7 is a low maintenance sensor that is ideal for installation as part of a SPAC monitoring system.
- TDR-310/315:
- ET:
- Vaisala HMP155: The HMP155 provides a highly accurate, traceable, temperature and humidity probe for leading research applications. Individually adjusted and calibrated using a six-point calibration across humidity ranges from completely dry to near saturated, the HMP155 is the temperature and humidity sensor for high quality measurements.
- Wind (Windsonic 75):
- Rain (RIM-7499-BOM):
- Pyranometer (SP-421):
- Power System: Supplied with the Low Power system containing a 10-watt solar panel and matching mount, and an internal 6,000mAh battery. The power system can be expanded with a supplementary 10-watt solar panel and mount to provide additional charge when used in low light conditions (EP-L).
-