Datalogger/Node Platform – DNP
Dedicated Environmental Datalogging and Communication Platform
An integrated solution from sensor combinations to datalogger, and through the communication options to the dashboard, the ICT International Datalogger Node Platform (DNP) is optimised for >use in soil, plant, and environmental decision making.
Designed, developed, and manufactured in Australia, the DNP draws on the global experience of ICT International in the supply and support of sensors for scientific and commercial research.
Page Contents
About the Platform
A dedicated environmental datalogging and communication platform providing edge processing of sensor data, data storage, and optional control functions, the DNP is built around these core principles:
- Scientific-grade resolution
- Time aligned measurements based on internal RTC
- 24-bit analogue channels
- Independent control of SDI-12 and RS485 channels
- Robust sensor management
- Low code configuration for SDI-12 and RS485 sensors
- Electronic isolation of SDI-12 and RS485 sensors ports
- Multiple SDI-12 or RS485 (when specified) ports can be run simultaneously, even if sensor does not support concurrent measurement.
- Distributed wireless loggers reduce cable infrastructure
- Programmable and customisable to suit application
- Store everything, process and send some.
- Data is stored before any other process is performed
- Onboard edge calculations optimise data transmission and simplify visualisation
- Interoperability with 3rd party database and visualisation platforms due to onboard processing – data is sent ready to be displayed, no additional work required
Logger Versions
A completely integrated datalogging, sensor management, and data processing platform, the DNP comprises four key products:
- Multifunction Logger: Expandable data management hub for wired and wireless sensor networks with options for radio communications (Cellular, Satellite) or wired (Ethernet), input boards, and power supply/management. Internal 4th Gen LoRa radio for wireless sensor collection
- Datalogger: Fixed sensor input configurations with radio (LoRa/LoRAWAN or CAT-M1/NB-IoT). and wired (CANBUS or Single Pair Ethernet) communication options. Less constrained by power requirements and measurement frequency due to rechargeable battery compared to a Uni-Logger
- Uni-Logger: Provide datalogging and wireless communication for low power sensors depending on power requirements and measurement frequency.
- Integrated Uni-Logger: Enable simultaneous measurement of plant water relations with up to 2 additional sensors (depending on power requirements and measurement frequency). Provide datalogging and wireless communication. On board calculation of sensor outputs to actionable data.
When used in conjunction with Uni-Loggers, the Multifunction Logger collects the sensor data logged on the Uni-Logger(s), stores the data in a dedicated relational database, before transmitting the data to visualisation platform(s) or allowing access for offline data processing for research applications.
When to Choose
Choose the Multifunction Logger when:
- implementing a distributed sensor network using UniLogger/Integrated UniLogger as sensor interface
- combining distributed sensors and a reference point (e.g. flux tower or large reference weather station)
- setting out complex
- laboratory sensor set up with multiple sensors connected via the interface board(s)
- field installations that use sensors with high power requirements (with external power supply)
- data redundancy and storage is required
- on-board processing of data to minimise transmitted payload size
- configurable for on-premise data storage and management – no internet connection required
Choose the Datalogger when:
- planning a single collection site that requires cellular or LoRaWAN backhaul
- multiple (3+) sensors are required using one or more input protocols
- retrofitting or upgrading an existing sensor network – no need to change SDI-12 sensor configurations
Choose the Uni-Logger when:
- multiple sites that require a couple (1 or 2) of sensors that are the same input type
- Multifunction Logger or an existing LoRaWAN is available
- low power sensors are in use (<10mA)
- long term installations or difficult to access – primary cell specified to provide 12 months power
- inconspicuous installation is needed – does not use a solar panel
Choose the Integrated Uni-Logger when:
- multiple sites within network range of the Multifunction Logger or existing LoRaWAN
- sap flow is being measured alongside another parameter (e.g. dendrometer, soil moisture)
- psychrometer is being measured alongside another parameter (e.g. dendrometer, soil moisture, in canopy VPD)
Functional Details
For all versions, the SDI-12 or RS485 channels are independently controlled, allowing no-address installation when using 1 sensor per port.
Multifunction Logger: the data logging, processing, and communication backbone of the platform.
- Onboard Linux based processor for data storage and processing
- Data stored in a relational database structure
- Internal LoRa Gateway: Receives data from Uni-Loggers using 4th Generation LoRa
- Optional interface boards:
- Enclosure based, bare wire terminal blocks. Ideal for laboratory or larger sensor installations
- All-in-one field: IEC standard IP67 connectors. Ideal for compact field installations in conjunction with Uni-Loggers
- Outbound communication options include:
- Cellular
- LoRaWAN (depending on number of sensors connected)
- Satellite via ethernet connection
- RS485 input/output
Datalogger: high-performance datalogging, storage, and processing platform with optional radio communication
- All-in-one field unit with IEC standard IP67 connectors. Ideal for retrofitting existing sensor installations
- -02: 8x SDI-12 Inputs and pulse counter (rain gauge)
- -03: 6x SDI-12, 2x RS-485, and pulse counter
- -04: SDI-12, RS-485, Analogue, and pulse counter
- Radio Communications include:
- LoRaWAN (-L)
- Cellular (-C)
- Satellite (in development)
- Rechargeable battery with onboard solar charge controller
Uni-Logger(s): self-contained logging sensor interfaces that convert common SPAC sensor signals to LoRa for connection to the Multifunction Logger or a LoRaWAN gateway.
- Input Options
- SDI-12 (2), RS485 (1) and Digital (1)
- RS485 (3) and Digital (1)
- Analogue (3) and Digital (1)
- 6V or 7.2V primary cell versions (20Ah/72Wh or 20Ah/144Wh)
- Robust aluminium extrusions
- IEC standard connectors
Integrated UniLogger: integrated sensor interface with LoRa/LoRaWAN module and rechargeable power system
- Sap Flow Sensor
- Psychrometer
Product Support
Case Studies
-
No case studies found