dT2t-SDI Delta-Temperature Paired Thermocouples
Delta temperature measurement for inversion layer and spray drift monitoring
Paired T-type thermocouples designed specifically for inversion layer and spray drift monitoring
ICT International’s dT2T-SDI paired T-type thermocouples (Copper/Constantan) provides a highly accurate delta temperature measurement, designed specifically for inversion layer and spray drift monitoring.
The lower thermocouple is used as the reference temperature (absolute), the upper thermocouple provides the measured delta temperature, both values are output in SDI-12 format.
On this Page
Any questions?
Email: sales@ictinternational.com.au
Phone: 02 6772 6770 (between 9am to 5pm New South Wales time)
Schedule a meeting with our expertsDT2T Specifications
- Time response @ 1 m/s: 90 sec.
- Max temperature difference: 10 K
- Max distance between sensors: 10 m
- Operating temperature range: -40 to 60 deg.C
- Power supply voltage: 5 to 16 V
- Holder for 50 mm tube.
Support Documents
| Integrators Guide | How To Articles | Download |
Case Studies and Application Notes
-
No case studies found