AWQ-CTZN Inductive Conductivity/Salinity Sensor
Overview
Features
Details
Specifications
Case Studies and Downloads
Overview
The CTZN Inductive Conductivity/Salinity sensor measures conductivity, salinity and temperature in water. Using induction conductivity, the sensor is designed for low maintenance and long term installation.
Available in either PVC or stainless steel versions.
The sensor is internally calibrated, the sensor stores calibration data internally for quick deployment when sensors are exchanged.
Applications include measurement of urban wastewater and industrial effluent treatment, surface and sea water monitoring.
The sensor can output RS485 or SDI-12 signals from the same sensor.
Features
Details
INDUCTIVE METHOD
A ring-type coil is excited at fixed intervals and the response is measured by a second coil, which is linked to the excited coil. The connectivity between the coils (determined by the degree of conductivity) takes place via the conducting solution.
The CTZN uses low-cost technology that requires little maintenance and no consumables.
- Temperature regulated sensor
- Range 0 to 100 mS/cm
- Modbus RS-485 and SDI12
- Compact, robust and watertight
MEASURED PARAMETERS
- Conductivity compensated in temperature (mS/cm)
- Conductivity non-compensated in temperature (mS/cm)
- Salinity (g/Kg)
- Temperature (°C)
APPLICATIONS
- Urban wastewater treatment
- Industrial effluent treatment
- Surface water monitoring
- Sea water
- Fish farming
Specifications
Measurement: | |
Measurement Principle: | Inductive conductivity sensor, temperature regulated |
Measurement Range (Conductivity): | 0 to 100 ms/cm |
Resolution: | 0.1 ms/cm |
Measurement Range (Salinity): | 5-60 g/Kg |
Temperature Compensation: | Inbuilt NTC or external measurement |
Accuracy T°C: | ± 0.1°C, range 0-40°C |
Response Time: | 90% of the value in less than 30 seconds |
Signal Interface: | Modbus RS-485 standard
SDI-12 optional |
Measurement Interval: | 1Hz |
Sensor Power Supply: | 5 to 30 volts max. |
Current Draw: | Automatic Standby: < 50 μA, Heating time 100 ms
Average Modbus RS485 – Range 0-100 ms/cm: 1Hz:
|
Max. current pulse: | 700 mA/2 ms
350 mA/ 150ms |
Sensor: | |
Operating Temperature: | 0 to 50°C |
Storage Temperature: | -10°C to +60°C |
Dimensions: | |
Diameter: | 62.4mm |
Length: | 196mm |
Weight: | 700g |
Material: | EPDM, PVC, Stainless steel |
Maximum Pressure: | 5 bar |
Connection: | 9 armoured connectors, polyurethane jacket, bare-wires or waterproof Fischer connector |
Protection: | IP68 |
Case Studies and Downloads