Introducing the new PV monitoring package designed to work with an SMA cluster controller. The package includes a silicon-cell pyranometer with a mounting bracket, Class A PRT back-of-panel temperature sensor with Kapton tape, fan-aspirated solar radiation shield with 24V - 12V DC converter, and Class A PRT air temperature sensor with TS-100 port adapter.
SP-214 Silicon-cell Pyranometer Specifications | |
Power Supply | 5 to 36 V DC with a maximum current drain 22 mA (2 mA quiescent current drain) |
Sensitivity | 0.013 mA per W mˉ² |
Calibration Factor | 78 W mˉ² mA (reciprocal of sensitivity) with an offset of 4.0 mA |
Calibration Uncertainty | ± 5% |
Calibrated Output Range | 4 to 20 mA |
Measurement Repeatability | Less than 1 |
Non-stability (Long-term Drift) | Less than 2% per year |
Non-linearity | Less than 1% (up to 1250 W mˉ², maximum radiation measurement is 1250 w mˉ²) |
Response Time | Less than 1 ms |
Field of View | 180˚ |
Spectral Range | 360 to 1120 nm (wavelengths where response is 10% of maximum) |
Directional (Cosine) Response | ±5% at 75˚ zenith angle |
Temperature Response | 0.04 ± 0.04% per C |
Operating Environment | -40 to 70°C, 0 to 100% relative humidity, can be submerged in water up to depths of 30 m |
Dimensions | 24 mm diameter, 28 mm height |
Cable | 5 m of shielded, twisted-pair wire with santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions) |
Mass | 140 g (with 5 m of lead wire) |
Warranty | 4 years against defects in materials and workmanship |
CS240 Back-of-Panel Temperature Sensor Specifications | |
Element Type | Precision 1000 Ω class A platinum sensing element |
Tolerance | ± (0.15 + 0.002t) |
Temperature Coefficient | TCR = 3850 ppm/K |
Long-Term Stability Maximum | R0 drift 0.04% (after 1000 h at 400°C) |
Measuring Current | 0.1 to 0.3 mA |
Operating Temperature Range | -40 to 105°C |
Disk Material | Anodised aluminium |
Cable Jacket Material | Black semi-gloss PVC, UL VWˉ¹ sunlight-resistant for outdoor use |
Disk Diameter | 25.4 mm |
Overall Probe Length | 63.5 mm |
Overmolded Joint Dimensions | 57.2 x 11.2 x 14.7 mm |
ST-150 Class A PRT Specifications | |
Measurement Range | -50 to 70°C |
Measurement Uncertainty | 0.3°C (-40 to 60°C), Class A |
Measurement Repeatability | Less than 0.01°C |
Long-term Drift | Less than 0.05°C per year |
Equilibration Time | 15 seconds |
Self-heating | Less than 0.01°C (typical, assuming pulsed excitation of 2.1 V DC), 0.09 at 5°C (max. assuming continuous input excitation of 2.1 V DC) |
Operating Environmental | -50 to 70°C, 0 to 100% relative humidity |
Input Voltage Requirement | Datalogger dependent |
Output Voltage Requirement | Datalogger dependent |
Current Draw | Datalogger dependent |
Dimensions | 56 mm, 3 mm diameter |
Mass | 95 g |
Warranty | 4 years against defects in materials and workmanship |
TS-100 Fan-Aspirated Radiation Shield Specifications | |
Difference among Individual Replicate Shields | Less than 0.1°C |
Aspiration Rate | 6 m sˉ¹ at full-speed, 3 m sˉ¹ at half-speed |
Fan Input Voltage Requirement | 10.8 to 13.2 V DC |
Fan Current Drain | 80 mA at full-speed, 25 mA at half-speed |
Fan Dust and Water Protection | IP55 |
Dimensions | 220 mm height, 270 mm diameter |
Mass | 840 g |
Cables | 5 m of shielded, twisted-pair wire for fan and air temperature sensors with santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions), pigtail lead wires |
Warranty | 4 years against defects in materials and workmanship |