This promotional package includes both an Apogee SQ-110 Original Quantum PAR Sensor with a 30 cm cable and microCache Bluetooth micro-logger. When paired, these two devices are a powerful tool for monitoring photosynthetically active radiation with research-grade accuracy for optimal plant growth.
The SQ-110 sensor is a trusted industry standard for making accurate PPFD measurements.
The new AT-100 microCache (µCache) micro-logger is a rugged, standalone, battery-powered device that can collect over 400,000 data points and connects your sensor to your iOS or Android device via Bluetooth using our ApogeeConnect app. The app allows you to make real-time measurements, set custom datalogging intervals, monitor and graph daily lights integrals, measure photoperiods, download datasets, and more.
Alternatively, the PQ110 Package comes with a 2M length cable.
µCache (AT-100) | |
---|---|
Communication Protocol | Bluetooth® Low Energy (Bluetooth 4.0+) |
Bluetooth Range | approx. 45 m (line-of-sight) |
Data Logging Capability | Averaging Interval: 1-60 minutes Sampling Interval: ≥ 1 second |
Data Log Capacity | Over 400,000 Entries (approx. 9 months at a 1-minute logging interval) |
Time Accuracy | ± 30 seconds per month at 0° C – 70° C |
Battery Type | 2/3 AA 3.6 Volt Lithium Battery |
Battery Life (impacted by sampling interval and amount of time connected to a mobile app) |
approx. 1 year w/ 10-second sampling interval and an average of 5 minutes daily connected time approx. 2 years w/ 60-second sampling interval and an average of 5 minutes daily connected time |
Operating Environment | -40 to 85 C |
Dimensions | 66 mm length, 55 mm width, 18 mm height |
Weight | 52 g |
IP Rating | IP67 |
Connector Type | M8 |
ADC Resolution | 24 bits |
SQ-110/120 | |
Power Supply | Self-powered |
Output (Sensitivity) | 0.2 mV per µmol m-2 s-1 |
Output Type | 0 to 800 mV |
Resolution | – |
Calibration Factor (reciprocal of sensitivity) | 5 µmol m-2 s-1 per mV |
Calibration Uncertainty | ± 5 % |
Measurement Repeatability | Less than 0.5 % |
Long-term Drift | Less than 2 % per year |
Non-linearity | Less than 1 % (up to 4000 µmol m-2 s-1) |
Response Time | Less than 1 ms |
Field of View | 180° |
Spectral Range | 410 to 655 nm (wavelengths where response is greater than 50 % of maximum) |
Spectral Selectivity | Less than 10 % from 469 to 655 nm |
Directional (Cosine) Response | ± 5 % at 75° zenith angle |
Temperature Response | 0.06 ± 0.06 % per C |
Operating Environment | -40 to 70 C; 0 to 100 % relative humidity; |
can be submerged in water up to depths of 30 m | |
Dimensions | 24 mm diameter, 33 mm height |
Mass (with 5 m of cable) | 90 g |
Package | Cable Length |
PQ-100 | 30 cm |
PQ-110 | 2 metres |