The Acclima DataSnap is the simplest standalone SDI-12 universal data logger available on the market today. While simple to use, it does not sacrifice features or functionality.
DataSnap is an SDI-12 data logger accommodating up to 10 SDI-12 sensors.
DataSnap is compatible with all sensors that communicate using the SDI-12 protocol.
Just connect an SDI-12 sensor and click a button in the SnapView Software. It requires no SDI-12 programming knowledge. Adding Acclima sensors is even easier as the DataSnap will find all attached Acclima sensors with the click of a button.
Acclima SnapView software simplifies DataSnap configuration and synchronisation via USB. It can manage multiple DataSnap connections and retrieve real-time sensor data from each. SnapView provides options for viewing data in table or graph formats. Data is easily exported for use in other analytical applications. SnapView is compatible with any Windows based PC (XP or newer)
Physical Characteristics | |
Length: | 10.5 cm |
Width: | 5.3 cm |
Height: | 2.5 cm |
Environmental | |
Operating Temperature: | -20 to +60°C |
Humidity: | 0 to 90% RH, non-condensing |
Electrical Specification | |
USB Port | |
Input Voltage: | 5VDC, ±0.5V |
Input Current: | 500mA Max |
External Supply Input (optional) | |
Input Voltage: | 6 – 12VDC, 15V Absolute Max |
Input Current: | 700mA Max |
Connector Type: | 2.1mm barrel, center positive |
SDI-12 Output | |
Signal Voltage: | Typically 0-5V DC |
Power Output Voltage: | (Input Voltage)-0.5V. Voltage may drop when short circuit protection is active |
Short Circuit Current: | 225mA ±10% |
Power Consumption (12V External Power Supply) | |
USB Active, No Load/Sensors: | 35mA |
USB Disconnected, Logger Active: | 8mA |
USB Disconnected, Logger Sleeping, IDLE_POWER=ON (Output Active, No Sensors) | 1.1mA |
USB Disconnected, Logger Sleeping, IDLE_POWER=OFF (Output Power Off) | 60uA |