The DUAL-PAM is a P700 and Chlorophyll Fluorescence Measuring System for photosystem II and photosystem I activities.
Available in two versions, the DUAL-PAM-100 (modular power and control unit) and DUAL-PAM/F (Fibre version) is a highly customisable system with the inclusion of accessory sensors.
Features
Details
- DUAL-PAM/F Fibre optics Version for simultaneous measurements of Chl fluorescence (PS II) and P700 absorbance changes (PS I), particularly for measurements in the field and with opaque samples that do not allow P700-measurements in the transmission mode. Control Unit with connectors for the Special Fibre optics 2010-F, as well as for either Mini Quantum Sensor US-MQS/WB or Leaf Clip Holder 2030-B or Mini Quantum/Temp. Sensor 2060-M. Including DualPAM Software (Windows 7/8/10) for operation of measuring system via PC, data acquisition and analysis. Including Special Fibre optics 2010-F, USB cable, Battery Charger (to charge internal battery) and Transport Box with room for Basic System and Accessories. All optical and electronic components are contained in the Control Unit: P700-Dual-Wavelength-Emitter Array (830 and 875 nm); red LED-Array (635 nm) for excitation of Chl fluorescence; fluorescence and P700 Detector/Pulse Preamplifier; red Chip-On-Board LED Array (635 nm) for continuous actinic light, saturating Single Turnover flashes (width from 5 to 50 μs) and Multiple Turnover flashes (width from 1 to 1000 ms); blue LED (460 nm) for continuous actinic light; far-red LED (730 nm) for preferential illumination of PS I.
- DUAL-PAM-100 Power-and-Control-Unit to connect the Measuring Heads DUAL-DB (DR, DP515, DAO or DNADPH) and DUAL-E (EP515, EAO or ENADPH), Miniature Magnetic Stirrer PHYTO-MS and the Spherical Micro Quantum Sensor US-SQS/WB. Including DualPAM Software (Windows 7/8/10) for operation of measuring system via PC, data acquisition and analysis; USB cable; Battery Charger, to charge internal battery. Including Stand ST-101 with Leaf Holder for mounting the Measuring Heads; Transport Box with room for Basic System and Accessories.
Specifications
 | Power-and-Control-Unit DUAL-C | FIBER Version DUAL-PAM-100 |
General design: | Â 2 x AVR-RISC microcontroller (8 MHz) + 4 MB SRAM; 256,000 data points with 12 bit resolution can be stored | Microcontroller: 2 x AVR-RISC (8 MHz) + 4 MB SRAM; 256 000 data points with 12 bit resolution can be stored |
PC interface: | USB 1.1, 2.0 and 3.0 compatible | USB 1.1, 2.0 and 3.0 compatible |
User interface: | Windows computer with DualPAM software | Windows computer with DualPAM software |
Power supply: | Rechargeable sealed lead-acid battery 12 V/2 Ah; Battery Charger MINI-PAM/L (100 to 240 V AC) | Rechargeable sealed lead-acid battery 12 V/2 Ah; Battery Charger MINI-PAM/L (100 to 240 V AC) |
Power consumption: | During basic operation 160 mA | During basic operation 160 mA |
Sockets: |
|
|
Measuring light: | P700-dual-wavelength-emitter: Sample wavelength 830 nm, reference wavelength 870 nm. Fluorescence emitter: 620 nm | |
Actinic red light: | Far-red LED lamp: 720 nm. Chip-on-board (COB) LED array: 635 nm for continuous actinic illumination, maximum 4000 μmol m-2 s-1 PAR. Saturating single turnover flashes, maximal 200 000 μmol m-2 s-1 PAR, adjustable between 5 and 50 μs. Multiple turnover flashes, maximal 20 000 μmol m-2 s-1 PAR, adjustable between 1 and 1000 ms. | |
Actinic blue light: | Blue LED lamp: 460 nm for continuous actinic illumination, maximal 500μmol m-2 s-1 PAR. | |
Signal detection: | PIN photodiode with special pulse preamplifier for measuring P700 and fluorescence changes with maximal time resolution of 10 μs | |
Dimensions: | 31 cm x 16 cm x 33.5 cm (W x H x D), with carrying handle | 31 cm x 16 cm x 33.5 cm (W x H x D), with carrying handle |
Weight: | 4.5 kg | 4.5 kg |