DEN Dendrometer Sensor Meters
Dendrometer Sensor Meters are designed for continuous plant growth measurements and available in three configurations
Measuring plant growth over a continuous basis will provide crucial information for resource optimisation (eg, water, fertiliser) during the plant growth period. .
The DEN range of Dendrometer Sensor Meters share a common logger configured for each sensor type. All loggers store data on a local microSD card for downloading for analysis on a local computer.
The DEN Dendrometer loggers are available in the following configurations:
- DEN1 for DBV60 Band Dendrometer (maximum 5 sensors)
- DEN3 for DEX fruit dendrometers (maximum 4 sensors)
- DEN6 for Ecomatik Dendrometers (maximum 5 sensors)
On this Page
Any questions?
Email: sales@ictinternational.com.au
Phone: 02 6772 6770 (between 9am to 5pm New South Wales time)
Schedule a meeting with our expertsSpecifications
| Â | Â | DEN1 | DEN6 |
| Instrument Logging | Analogue Channels | 5 Differential | 5 Single Ended (channel 1 of 10 total is 2.5V sensor excitation measurement) |
| Resolution | 0.00001V—24-Bit | ||
| Accuracy | 0.001V | ||
| Minimum Logging Interval | 1 second | ||
| Delayed Start | Suspend Logging, Customised Intervals | ||
| Sampling Frequency | 10Hz | ||
| Data | Data Communications | USB | |
| Data Storage | MicroSD Card, SD, SDHC & SDXC Compatible (FAT32 format) | ||
| Data Compatibility | FAT32 compatible for direct exchange of SD card with any Windows PC | ||
| Data File Format | Comma Separated Values (CSV) for compatibility with all software programs | ||
| Memory Capacity | Up to 16GB, 8GB microSD card included. | ||
| Operating Conditions | Temperature Range | -10°C to +50°C | |
| R/H Range | 0-100% | ||
| Upgradable | User Upgradeable firmware using USB boot strap loader function. | ||
| Power | Internal Battery Specifications | 960mAh Lithium Polymer, 4.20 Volts fully charged | |
| External Power Requirements | 10W, 20V solar panel minimum | ||
| Bus Power | 8-30 Volts DC, non-polarised, current draw is 190mA maximum at 17 volts per logger | ||
| USB Power | 5 Volts DC | ||
| Internal Charge Rate | Bus Power | 60mA – 200mA Variable internal charge rate, maximum charge rate of 200mA active when the external voltage rises above 16 Volts DC | |
| USB Power | 100mA fixed charge rate | ||
| Internal Power Management | Fully Charged Battery | 4.20 Volts | |
| Low Power Mode | 3.60 Volts – Instrument ceases to take measurements | ||
| Discharged Battery | 2.90 Volts – Instrument automatically switches off at and below this voltage when no external power connected. | ||